powerferro.blogg.se

Brocade san switch netapp array l-port to f-port
Brocade san switch netapp array l-port to f-port












brocade san switch netapp array l-port to f-port

Whichever of these two (addressing mode or the value configured through portCfgNPIVPort) is lower will be the maximum number that can be logged in. The portCfgNPIVPort command can set the maximum number of NPIV logins limit to anything from 1 through 255, regardless of the addressing mode. The addressing mode can limit the maximum number of NPIV logins to 127 or 63 depending on the mode. If the NPIV feature has been disabled, then the NPIV port configuration does not work. Once NPIV is enabled on the port, you can specify the number of logins per port. It can also be used to enable or disable NPIV. The portCfgNPIVPort command is used to specify the maximum number of virtual N_port IDs per port on a switch. You can set the number of virtual N_Port IDs per port to a value from 1 through 255 per port. NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON Trunk Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN The following example shows whether a port is configured for NPIV:

  • Enter the portCfgShow command to view the switch ports information.
  • Connect to the switch and log in using an account assigned to the admin role.
  • Viewing NPIV port configuration information Therefore your setup with UCS should work, without any special setup on the Brocade (Zoning of course needs to done).

    brocade san switch netapp array l-port to f-port

    This operand is optional if omitted, the default value of 0 is used.Sorry for the confusion: putting a Brocade switch to AG mode is disruptive the switch will reboot this corresponds to a MDS NPV mode !īy default, NPIV is enabled, see below. on the brocade switch the port is an F port and I can see that the FIs are showing up on the brocade switch via the port HBA WWPNs. Specify 0 to configure the L_Port as a full-duplex L_Port. I got my brocade switch attached to my fabric interconnects. On all other platforms, option 1 is blocked.ĭuplex_mode Specify 2 to configure the specified port as a full-duplex L_Port with fairness. Private devices are supported only on Brocade enterprise-class platforms with FC2-16 and FC2-16 blades. This operand is optional if omitted the default value of 0 is used. Specify 0 to configure the L_Port as a regular public L_Port. Private_mode Specify 1 to configure the L_Port as a private L_Port. This operand is required if port is specified. Specify 0 to remove the locked L_Port configuration from the port (default). Locked_mode Specify 1 to configure the specified port as a locked L_Port. This operand is optional if omitted, this command displays the L_Port conditions for all ports. Use switchShow to display a list of valid ports. Port Specify a port number to be configured, relative to its slot for bladed systems. Slot For bladed systems only, specify the slot number of the port to be configured, followed by a slash (/).

    brocade san switch netapp array l-port to f-port

    When invoked without operands, this command reports the L_Port conditions for all ports present. It can be configured as a private L_Port, in which case it will reject fabric login (FLOGI). To configure an IP address of 192.168.0.10 and a netmask of 255.255.255.0 on the singlemode interface group SingleTrunk1. By default the L_Port will be a public L_Port. Create (single-mode) To create a single-mode interface group, enter the following command: ifgrp create single SingleTrunk1 e0 e1 e2 e3. The switch will never attempt a point-to-point (F_Port) initialization on the port. When a port is designated as an L_Port, the switch attempts to initialize that port as a fabric L_Port (FL_Port). There is a command called portCfgLport, you can use this command to designate a port as an L_Port, and to configure its behavior.














    Brocade san switch netapp array l-port to f-port